DataTalk

Environment & Power

Environmental and power conditions for the DataTalk IPC — non-condensing environment, temperature for long life, ventilation, stable power supply and UPS.

On this page

These conditions apply to the DataTalk IPC. If DataTalk runs on your own server, follow the conditions of its manufacturer.

Non-condensing environment

A condensing environment causes permanent damage to the device — water moisture corrodes the PCB and leads to a hardware malfunction.

  • Operate the device in a dry environment only.
  • Rated humidity: 5 % to 95 % RH, non-condensing.

Temperature

Value
Rated operating temperature−25 °C to +60 °C
Recommended for long-term 24/7 operationbelow 35 °C
Storage temperatureup to +70 °C (depending on the model)

The device works in the whole rated range, but operating above 35 °C results in limited performance and a shortened device life. The RTC battery is affected the most.

  • Provide ventilation of the cabinet.
  • Keep free space around the device.

Power supply

The DataTalk IPC is designed to operate from a stable power supply.

Value
Input voltageDC 9–36 V (Phoenix-type 2-pin terminal)
Maximum power consumptionapprox. 24 W
Recommended power supply≥ 30 W
Protectionsover-voltage, over-current, reverse polarity
Use a UPS on machines that are switched off regularly

If the IPC is part of a machine that is regularly switched off, we strongly recommend a UPS that keeps the IPC running. Frequent power cycling shortens the life of the RTC battery and can cause unexpected data logging errors.

  • Provide a stable power supply with the rated voltage and current.
  • Do not leave the IPC without power for extended periods — the RTC battery depletes.

Full hardware specification: DataTalk IPC → Technical & Mechanical Specification.